JML-A SERIES FULL-AUTOMATIC COAL-FIRED HOT-AIR GENERATOR
1、100-150 thousands large calorie thermal capacity.
2、Heating s.m:600/1000m2.
3、Adopt the special design’s “Jienuo” 3th generation of high effective stainless steel heat
exchanger.
4、Optional configuration: computer control & numerical control.
5、automatic coal-burning product of the domestic origination with the most advanced automatic
stoking system
5、Special whole heat-prevention design, thermal capacity loss reduces to the lowest . Firebox all
adopts the heat-resistance 321 (1Cr18Ni9Ti) stainless steel
6、Heat efficiency up to 80%
7、All the requirements up to the national “I” environmental protection standard
JML-A FULL-AUTOMATIC COAL-FIRED HOT-AIR GENERATOR
Parameter |
Unit |
JML-A15 |
Fixed calorific capacity |
Kcal. |
150kilo. |
thermal efficiency |
% |
≥80 |
Hot air outlet temperature |
℃ |
40-65 |
Fixed hot air capacity |
m3/h |
20200 |
Fixed coal-burning capacity |
kg/h |
20-30 |
Adaptable fuel |
|
anthracite coal |
Fuel grain |
CM |
1-3 |
Figure |
mm |
2800×1200×2000 |
Weight |
kg |
980 |
Electricity |
V |
220/380V |
Heating s.m |
M2 |
>900 |
JML-D SERIES GREENHOUSE AUTOMATIC COAL-BURNING HOT AIR GENERATOR
Parameter |
Unit |
JML-5D |
JML-10D |
JML-20D |
Fixed calorific capacity |
Kcal. |
50kilo. |
100kilo. |
200kilo. |
thermal efficiency |
% |
≥90 |
≥90 |
≥90 |
Hot air outlet temperature |
℃ |
60-90 |
60-90 |
60-90 |
Fixed hot air capacity |
m3/h |
10000 |
20000 |
28000 |
Fixed coal-burning capacity |
kg/h |
10-15 |
15-25 |
25-35 |
Adaptable fuel |
|
anthracite coal/few bituminous coal |
anthracite coal/few bituminous coal |
anthracite coal/few bituminous coal |
Power |
Kw |
0.61 |
1.11 |
1.59 |
Figure |
mm |
1470×900×1930 |
1620×1050×2130 |
2000×1100×2130 |
Weight |
kg |
550 |
680 |
950 |
Electricity |
V |
220/380V |
220/380V |
220/380V |
Heating s.m |
M2 |
200-300 |
400-600 |
800-1200 |
JML-D2 SERIES POULTRY AUTOMATIC COAL-BURNING HOT AIR GENERATOR
Parameter |
Unit |
JML-5D |
JML-10D |
JML-20D |
Fixed calorific capacity |
Kcal. |
50kilo. |
100kilo. |
200kilo. |
thermal efficiency |
% |
≥70 |
≥70 |
≥70 |
Hot air outlet temperature |
℃ |
50-120 |
50-120 |
50-120 |
Fixed hot air capacity |
m3/h |
1131-2531 |
1688-6517 |
4012-7419 |
Fixed coal-burning capacity |
kg/h |
10-15 |
15-25 |
25-35 |
Adaptable fuel |
|
Low sulfur anthracite |
Low sulfur anthracite |
Low sulfur anthracite |
Power |
Kw |
1.6 |
2.31 |
5.6 |
Figure |
mm |
1470×900×1930 |
1620×1050×2130 |
2000×1100×2130 |
Electricity |
V |
220/380V |
220/380V |
220/380V |
|